DETEX

detex-standalone exit alarms-exit controls-firerated exit control locks
Back To Main Catagories

Detex

Standalone Exit Alarms

Detex-Standalone Exit Alarms

EAX300 BATTERY POWERED DOOR PROPPED ALARM
- The Detex EAX-300 series is designed for applications where doors may be used for egress or ingress, but may not be held or propped open. Door open times from 1 second to 2 minutes (15 second default) are field selectable. The smaller size makes installation quick and easy.
- Helps keep energy costs down by ensuring doors are closed.
- Quick, easy installation saves time and money.
- Alarm silences when door is closed, no waiting for key-holder to arrive.
- Secure, tamper resistant housing.
- Patented plastic template assures accurate installation by providing foolproof alignment with internal magnetic door contact.
- Tapered cover allows for installation on narrow stile doors, 2” minimum.
- Intelligent circuit senses the external magnet location automatically and sets the correct door handing.
- 100 dB piezo alarm.
- 9VDC battery operated with low battery alert.
- LED visual arming indicators.
- Size: 2.10”W x 7.7”H x 2.375”D.
- Mortise cylinder with standard Yale cam required (sold separately).
- Accepts 1”, 1-1/8” & 1-1/4” cylinders.

EAX500 STANDALONE BATTERY POWERED EXIT ALARM
- Self-contained door alarm with 100 dB piezo horn that sounds to warn unauthorized use of a door or gate.
- Secure, tamper resistant housing.
- Patented plastic template allows for foolproof alignment of internal magnetic door contact and accurate installation of unit.
- Tapered cover allows for installation on narrow stile doors that are 2” minimum width.
- Intelligent circuit senses the external magnet location automatically and sets the correct door handing.
- Size: 7.7”H x 2.1”W x 2.375”D.
- Patented cam assembly automatically adjusts for different sizes of cylinders without use of spacers.
- Extended bypass allows alarm to remain bypassed when door is open and automatically rearm upon door closing.
- 9VDC battery operated with low battery alert.
- Has LED visual and audible arming indicators.
- Field selectable 2-minute auto rearm, if desired.
- Field selectable status indicators if desired.
- Mortise cylinder with standard Yale cam required (sold separately).
- Accepts 1”, 1-1/8” & 1-1/4” cylinders.


Detex

Exit Control Locks, Accessories & Fire Rated Exit Control Locks

Detex-Exit Control Locks-Accessories and Fire Rated Exit Control Locks

EXIT CONTROL LOCK
- Attack resistant design withstands over 2200 lbs of outside pull force.
- Reduces internal and customer theft.
- Single point 1” throw saw resistant dead bolt.
- 100 decibel alarm, powered by 9-volt battery (included).
- Accepts 5-pin through 7-pin standard and interchangeable core rim cylinders.
- Durable steel plate with photo luminescent sign absorbs light to “glow in the dark” when lights are dimmed.
- Non-handed.
- Locking and unlocking the dead bolt always arms and disarms the alarm.
- Resetting the alarm can only be accomplished with a control key.

ACCESSORIES
ECL2111K
- Siren/battery conversion kit - for ECL-230C & D.
- Converts ECL-230 6 volt lantern battery to 9 volt battery & siren.
- ECL435K
- Adjustable surface strike bracket for some double door applications where one door is held closed with surface or flush bolts.
- For use on left hand, right hand inswinging doors or double doors with one door stationary using flush bolts or DDH-2250.
- ECL437K
- Adjustable surface strike for use with outswinging doors.
- PP5572
- Cover lock, nut, and 2 keys.
- 9 Volt Conversion Kit.
- Adjustable Surface Strike.
- Standard Strike.
- Cover Cam Lock for ECL230, EAX300 & EAX500.

ECL600 FIRE RATED EXIT CONTROL LOCKS
- Fire rated and code-compliant relatching exit device.
- Reduces internal and customer theft.
- 1” throw saw resistant dead bolt & 3/4” latching bolt.
- 100 decibel alarm, powered by 9-volt battery (included).
- Accepts 5-pin through 7-pin standard and interchangeable core rim cylinders.
- Durable steel plate with photo luminescent sign absorbs light to “glow in the dark” when lights are dimmed.
- Non-handed.
- Locking and unlocking the dead bolt always arms and disarms the alarm.
- Resetting the alarm can only be accomplished with a control key.


Detex

Hinge Bolts, Fire Rated Alarmed & Delayed Egress Exit Devices

Detex-Hinge Bolts-fire Rated Alarmed and Delayed Egress Exit Devices

HINGE BOLTS
- Provides hinge-side protection against break-ins
- Adds additional locking points, improving holding strength to slow down crowbar attacks.
- Easy to install.
- Can be added to almost any outswing door application.
- Choose the right level of protection with kits of 1 bolt, 2 bolts or 3 bolts.
- Kits include through-bolt mounting hardware.
- One piece stainless construction provides superior holding strength.
- Excellent for exterior application or that doors that get wet Single Hinge Bolt, Double Hinge Bolts, Triple Hinge Bolts.

V40 ALARMED & DELAYED EGRESS EXIT DEVICES
V40EB
- Reduces internal and customer theft while meeting building code requirements.
- Alarmed 100 decibel exit device powered by standard 9-volt battery.
- Stainless steel, 3/4” deadlocking Pullman-type latch bolt.
- Heavy-duty ribbed aluminum rail extrusion.
- Fits 36” doors, (can be cut down in the field) 1-3/4” to 2-1/4” thick with minimum 2-1/2” stiles.
- 1/8 turn of mortise cylinder provides dogging of the device.
- Controls foot traffic, deters unauthorized exits, and prevents loss.
- Heavy-duty angled end cap.
- Accommodates all sizes of mortise cylinders with a standard Yale cam; collar is required for 7-pin IC cylinders.
- Patented back plate and plastic strike locator provide paperless template for perfect alignment of unit on door and frame.
- Field selectable key rearm or 2 minute auto rearm.
- Visual and audible arming indicators status are field selectable.
- V40EE
- All the features of the V40EB above with delayed egress.
- Powered by regulated power supply that delivers a constant 24VDC of filtered and regulated voltage at a rated load of 1A.
- Fire alarm input can be connected at power supply.
- Remote signal output and remote bypass input standard.
- Includes delayed egress panic bar, 24VDC filtered and regulated power supply, 3’ confuit loop and door sign that says “PUSH UNTIL ALARMS SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS”.
- 9V battery provides alarm function only in case of power failure Standard, Delayed Egress.